BR550GI Features
APC Power-Saving Back-UPS Pro 550
-
Audible alarmsProvides notification of changing utility power and UPS power conditions
-
Automatic self-testPeriodic battery self-test ensures early detection of a battery that needs to be replaced.
-
Automatic Voltage Regulation (AVR)Automatically steps up low voltage and steps down high voltage to levels that are suitable for your equipment.
-
Battery failure notificationProvides early-warning fault analysis on batteries enabling timely preventive maintenance
-
Battery replacement without toolsEnables fast battery replacement, lowering Mean Time to Repair (MTTR).
-
Battery-protected and surge-only outletsReserves power capacity and run time for connected equipment that require UPS battery back-up while providing surge only protection for less critical equipment
-
Boost and Trim Automatic Voltage Regulation (AVR)Eliminates voltage fluctuations as a source of AV signal degradation and component power-supply stress.
-
Cold-start capableProvides temporary battery power when the utility power is out.
-
Dataline surge protectionProvides protection of connected equipment from power surges on the data lines.
-
Disconnected battery notificationWarns when a battery is not available to provide backup power.
-
Green modePatent-pending operating mode that bypasses unused electrical components in good power conditions to achieve very high operating efficiency without sacrificing any protection.
-
Hot-swappable batteriesEnsures clean, uninterrupted power to protected equipment while batteries are being replaced
-
LCD graphics displayText and mimic diagrams that display modes of operation, system parameters and alarms.
-
Power-saving outletsAutomatically cuts power to idle equipment to conserve electricity.
-
Safety-agency approvedEnsures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment.
-
USB connectivityProvides management of the UPS via a USB port (not available on all models).
-
User-replaceable batteriesIncreases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR)
Back-UPS Pro Features & Benefits
Manageability
-
USB connectionUse your PC to access additional power protection and management features for your UPS via a USB Port.
-
LCD Status DisplayProvides key UPS status at a glance. Multiple status indicators with load and battery bar graphs.
-
Audible alarmsProvides notification of changing utility power and UPS power conditions
-
Disconnected battery notificationWarns when a battery is not available to provide backup power.
Marketing Features
-
Battery-protected and surge-only outletsReserves power capacity and run time for connected equipment that require UPS battery back-up while providing surge only protection for less critical equipment
-
LCD Status DisplayProvides key UPS status at a glance. Multiple status indicators with load and battery bar graphs.
-
Boost Automatic Voltage Regulation (AVR)Preserves battery life and maximizes runtime by correcting low voltages without discharging the battery.
-
Energy Management FunctionEnergy saving feature automatically power off peripherals when the a master device, usually a PC, hibernates or is shut down. Power to peripherals is immediately restored when the master device wakes up or is switched on.
-
Green modePatent-pending operating mode that bypasses unused electrical components in good power conditions to achieve very high operating efficiency without sacrificing any protection.
Serviceability
-
Resettable circuit breakerEasy recovery from overloads; no need to replace a fuse.
-
Simple battery replacementIncreases UPS availability by allowing quick, easy battery replacement.
Availability
-
Energy Management FunctionEnergy saving feature automatically power off peripherals when the a master device, usually a PC, hibernates or is shut down. Power to peripherals is immediately restored when the master device wakes up or is switched on.
-
Customizable voltage-transfer pointsAdjust the voltage points (widen or tighten the range) where your UPS transfers to battery to maximize useful battery life and protect sensitive electronics.
-
Customizable voltage sensitivityToggle between pre-determined voltage-transfer points depending on your power quality (high, medium or low sensitivity), maximizing useful battery life and protecting sensitive electronics.
-
Boost and Trim Automatic Voltage Regulation (AVR)Gives higher application availability by correcting low and high voltage conditions without using the battery (not available on all models).
-
Green modePatent-pending operating mode that bypasses unused electrical components in good power conditions to achieve very high operating efficiency without sacrificing any protection.
-
Automatic self-testPeriodic battery self-test ensures early detection of a battery that needs to be replaced.
-
Battery failure notificationProvides early-warning fault analysis on batteries enabling timely preventive maintenance
-
Cold-start capableProvides temporary battery power when the utility power is out.
-
Intelligent battery managementMaximizes battery performance, life, and reliability through intelligent, precision charging.
-
Transformer-block spaced outletsProtect equipment with input transformer blocks without blocking access to other receptacles.
Protection
-
Surge only outletsProtect secondary electronics from surges and spikes without reducing battery power used to run primary electronics during an outage.
-
Battery and surge protected outletsBack up and protect your hardware and data during power outages, surges and spikes.
-
Dataline surge protectionProvides protection of connected equipment from power surges on the data lines.
Safety
-
Safety-agency approvedEnsures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment.
Output
-
Output power capacity330 Watts / 550 VA
-
Max Configurable Power (Watts)330 Watts / 550 VA
-
Nominal Output Voltage230V
-
Output Frequency (sync to mains)50 Hz
-
TopologyLine Interactive
-
Waveform typeStepped approximation to a sinewave
-
Output Connections(3) IEC 320 C13 (Battery Backup)(3) IEC 320 C13 (selector_surgetitle)
-
Transfer Time6ms typical : 10ms maximum
Input
-
Nominal Input Voltage230V
-
Input frequency50/60 Hz +/- 3 Hz (auto sensing)
-
Input ConnectionsIEC-320 C14
-
Input voltage range for main operations176 - 282 V
-
Input voltage adjustable range for mains operation155 - 290 V
-
Maximum Input Current6.0 A
Batteries & Runtime
-
Battery typeMaintenance-free sealed Lead-Acid battery with suspended electrolyte : leakproof
-
Typical recharge time12 hour(s)
-
Replacement BatteryAPCRBC110
-
RBC Quantity1
-
Battery Volt-Amp-Hour Capacity66
-
Runtime
-
Efficiency
Communications & Management
-
Interface Port(s)Optional Simple Signalling RS232 cable , USB
-
Control panelMulti-function LCD status and control console
-
Audible AlarmAlarm when on battery : distinctive low battery alarm : overload continuous tone alarm
Surge Protection and Filtering
-
Surge energy rating420 Joules
-
Data Line ProtectionNetwork line - 10/100/1000 Base-T Ethernet (RJ-45 connector)
-
FilteringFull time multi-pole noise filtering :10% of IEEE surge let-thgouh : zero clamping response time: instantaneous
Physical
-
Maximum Height190 , 19.0 cm
-
Maximum Width91 , 9.1 cm
-
Maximum Depth310 , 31.0 cm
-
Net Weight6.53 kg
-
Shipping weight7.71 kg
-
Shipping Height252 , 25.2 cm
-
Shipping Width138 , 13.8 cm
-
Shipping Depth442 , 44.2 cm
-
ColorBlack
-
Master Carton Units2.0
-
Master Carton Weight15.94
-
Units per Pallet48.0
-
SCC Codes1073130426688 1
Environmental
-
Operating Environment0 - 40 °C
-
Operating Relative Humidity0 - 95 %
-
Operating Elevation0-3000 meters
-
Storage Temperature-15 - 45 °C
-
Storage Relative Humidity0 - 95 %
-
Storage Elevation0-15000 meters
-
Audible noise at 1 meter from surface of unit45.0 dBA
Conformance
-
ApprovalsA-tick, C-tick, CE, GOST, GS Mark
-
Equipment protection policyLifetime : 200000 AUD, Lifetime : 150000 Euros, Lifetime : 75000 GBP
-
Standard warranty2 years repair or replace, 3 years repair or replace for European Union countries
Sustainable Offer Status
-
RoHSCompliant
-
REACHREACH: Contains No SVHCs
-
PEPAvailable in Documentation tab
-
EOLIAvailable in Documentation tab
Tehnologija | Ne |
---|---|
Izlazni oblik vala | Ne |
Robna marka | Ne |